Model: SF3R230_7.5x11.5_10A | ![]() |
Ordering Code: B023L7511500C |
Features |
Applications |
Standard size High current rating Very fast response time Stable performance over life Very low capacitance High insulation resistance RoHS-compatible |
Modem XDSL-splitter Data lines Tuner Antenna |
Electrical specifications:
DC spark-over voltage1) 2) |
230 ± 20 |
V % |
Impulse spark-over voltage2) |
||
100V/µs |
< 600 |
V |
1 KV/µs |
< 700 |
V |
Service life |
||
10 operations 50 Hz, 1 s3) |
10 |
A |
1 operations 50 Hz, 0.18 s (9 cycles)3) |
30 |
A |
10 operations[5x (+) & 5x (-)] 8/20 µs3) |
10 |
kA |
1 operation 8/20 µs3) |
15 |
kA |
1 operations 10/350 µs3) |
2.5 |
A |
Insulation resistance at 100 Vdc2) |
> 1 |
GΩ |
Capacitance at 1 MHz 0.5V2) |
< 2 |
pF |
Weight |
~1.5 |
g |
Operation and storage temperature |
-40 ~ +90 |
°C |
Marking |
3R 230 SF - Brand Name |
|
230 - Nominal voltage |
1) The voltage is measured with a low rate of rise dv / dt =100V/swww.ishumba.com
2) Tip or ring electrode to center electrodewww.ishumba.com
3) Total current through center electrode, half value through tip respectively ring electrode.www.ishumba.com
Terms in accordance with GB/T 9043-2008 and ITU-T Rec. K.12.www.ishumba.com
Dimensional drawing:
Cautions and warnings:
- Surge arresters must not be operated directly in power supply networks. www.ishumba.com
- Surge arresters may become hot in case of longer periods of current stress (danger of burning). www.ishumba.com
-
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.www.ishumba.com
- Damaged surge arresters must not be re-used.www.ishumba.com
![]() |